200W 250W Micro AC Motor Kit 220V Gear Motor Speed Forward and Reverse Controller+Single Phase Asynchronous Motor 50/60hz ForCNC

200W 250W Micro AC Motor Kit 220V Gear Motor Speed Forward and Reverse Controller+Single Phase Asynchronous Motor 50/60hz ForCNC

250W Controller Kit / 260rpm-(Ratio 1to5) / 1PH-220V
Precio de oferta  $36.00 Precio habitual  $45.00
Ir directamente a la información del producto
200W 250W Micro AC Motor Kit 220V Gear Motor Speed Forward and Reverse Controller+Single Phase Asynchronous Motor 50/60hz ForCNC

200W 250W Micro AC Motor Kit 220V Gear Motor Speed Forward and Reverse Controller+Single Phase Asynchronous Motor 50/60hz ForCNC

Precio de oferta  $36.00 Precio habitual  $45.00
Envío calculado en el pago.
Color
Dimensions
Set Type1PH-220V

SPECIFICATIONS

Brand Name: NONE

Origin: Mainland China

Power 1: 60W

Power 2: 120W

Power 3: 180W

Power 4: 200W

Power 5: 250W

Speed: 5-1350rpm

phase: single phase

voltage: 110v / 220v

1* Micro AC Gear Motor
1* Controller






























Working Condition1: When the load is small and the motor is not operating continuously for a long time, the speed regulator must not be set lower than 50% of the full speed

Working Condition2: When the load is small and the motor is not operating continuously for a long time, the speed regulator must not be set lower than 70% of the full speed



Description of Speed-regulating Safety Zone

Why can't the speed of the motor be set too low after it is loaded? Because the speed regulator reduces the speed by lowering the voltage, when the voltage is reduced, the motor speed decreases and the torque also drops, which can easily lead to overload and motor burnout. Additionally, when the motor speed is slowed down, the cooling fan will also rotate slowly, and the heat dissipation effect will deteriorate. At this time, due to the increase in current, the heat dissipation will deteriorate, causing the motor to heat up severely and easily resulting in insulation failure of the stator coil and short circuit burnout.



Please note that our forward and reverse controller, 110V, cannot be used directly due to its special voltage Additional switches are required for linking.

And during use, do not directly adjust the forward rotation to reverse rotation.
If it is running in forward rotation, you need to wait for the motor to stop before pressing reverse rotation.
If it is directly adjusted from forward rotation to reverse rotation, it is easy to burn out the controller after running for a long
time

 